Generate a screen
GENERATE DYNPRO h f e m ID g.
...MESSAGE F1 ...LINE F2 ...WORD F3.
Additions
1. ... OFFSET f4
2. ... TRACE-FILE f5
Effect
Generates the screen specified in the field g .Here, the source code is taken from the structure h and the internal tables f , e and m . The field h (screen header) should correspond to the structure D020S , the internal table f (field list) to the structure D021S , the internal table e (flow logic) to the structure D022S and the internal table m (match code information) to the structure D023S .
If a syntax error occurs, the error message is stored in the field f1 .If a syntax error occurs, the number of the incorrect line is stored in the field f2 .
By reading the return code value, you can determine whether this line refers to the flow logic or the field list.
If a syntax error occurs, the incorrect word is stored in the field f3 .
The return code value is set as follows:
SY-SUBRC = 0 The screen was generated.
SY-SUBRC <> 0 The screen could not be generated.
SY_SUBRC = 4 The error is in the flow logic.
SY-SUBRC = 8 The error is in the field list.
Addition 1
... OFFSET f4
Effect
If a syntax error occurs, the position of the incorrect word is output in this field.
Addition 2
... TRACE-FILE f5
Effect
Stores performance data in this file. This addition automatically switches on the trace mode.
Here you can try learning SAP ABAP SYNTAX FOR FREE KEY WORD.
The previous topic here is SAP ABAP BADI IMPLEMENTATION USING FORMULA BAR.
You like this information and would like to get updates.
Organizational Challenges with crm and mysap crm solutions
My sap crm and marketing planning
GENERATE DYNPRO h f e m ID g.
...MESSAGE F1 ...LINE F2 ...WORD F3.
Additions
1. ... OFFSET f4
2. ... TRACE-FILE f5
Effect
Generates the screen specified in the field g .Here, the source code is taken from the structure h and the internal tables f , e and m . The field h (screen header) should correspond to the structure D020S , the internal table f (field list) to the structure D021S , the internal table e (flow logic) to the structure D022S and the internal table m (match code information) to the structure D023S .
If a syntax error occurs, the error message is stored in the field f1 .If a syntax error occurs, the number of the incorrect line is stored in the field f2 .
By reading the return code value, you can determine whether this line refers to the flow logic or the field list.
If a syntax error occurs, the incorrect word is stored in the field f3 .
The return code value is set as follows:
SY-SUBRC = 0 The screen was generated.
SY-SUBRC <> 0 The screen could not be generated.
SY_SUBRC = 4 The error is in the flow logic.
SY-SUBRC = 8 The error is in the field list.
Addition 1
... OFFSET f4
Effect
If a syntax error occurs, the position of the incorrect word is output in this field.
Addition 2
... TRACE-FILE f5
Effect
Stores performance data in this file. This addition automatically switches on the trace mode.
Here you can try learning SAP ABAP SYNTAX FOR FREE KEY WORD.
The previous topic here is SAP ABAP BADI IMPLEMENTATION USING FORMULA BAR.
You like this information and would like to get updates.
Organizational Challenges with crm and mysap crm solutions
My sap crm and marketing planning
No comments :
Post a Comment